Finite H Series Compressed Air/Gas Filters (Up to 500 PSI)

Finite H Series is the right solution for most compressed air and gas applications. The filter elements are formed with special UNI-CAST glass microfibers to enhance the depth-loading characteristics of each element's fiber matrix. This design provides lower pressure drops and less frequent change outs, saving you time and money.

Large flow low energy modular compressed air dryers providing pressure dew points of -70°C and -40°C with flow rates up to 2040 m³/hr @ 7 barg, even greater flow rates can be achieved by multi-banking the dryers.

Call us TODAY at 727-847-4900 or
Toll Free at 800-761-4298

Get A Free Quote!

H Series Filter Selector

Choose your Element Grade, Element Type, End Seal, Port Type, Port Size, Bowl Size, and Accessories below. Then click "Submit" to generate the part number.
Your Selected Filter Part Number:

Step 1. Determine your element grade, element type and end seals.

1.) Choose Element Type and End Seal:
• Click Here for the Coalescing Element Guide
• Click Here for the 100WS, 3P, and A type Element Guide
• Click Here for the End Seal Guide


2.) Choose Element Grade for C, Q, D and I Element types ONLY: If 7CVP, 3P, 100WS, or A (Adsorber) Element Grade was Selected Above, Skip this Step
• Click Here for the Element Grade Guide

Step 2. Determine your housing

1.) Choose Port Type:


2.) Choose Port Connection Size:


3.) Choose Housing Assembly Size:
Housing length is determined by the flow rate and port connection size required. Determine if your required Housing Assembly is "Standard", "Long", or "Economy" Size. View the housing chart below to determine if the Housing Assembly you require ends in a "S" for Standard, "L" for Long, or "E" for ecomony and select below.
• Click Here To View Housing Size Chart
• Click Here To View Housing Size Chart for Gases Other than Air.

Step 3. Determine your Optional Accessories

1.) Choose Optional Accessories: Leave blank if no accessory is needed • Click Here for the Optional Accessories Guide

Click Submit after all correct options have been selected.
Your generated filter number will be dispalyed at the top.


• Build Your Own Model Number Chart
• Finite H Series Replacement Elements

Submicronic contaminants in compressed air systems plug orifices of sensitive pneumatic instrumentation, wear out seals, erode system components, reduce the absorptive capacity of desiccant air/gas dehydrators, foul heat transfer surfaces, reduce air tool efficiency, and damage finished products. The results include product rejects, lost production time and increased maintenance expense.

For example, trace amounts of submicronic oil can cause serious fish eye blemishing in automotive finishing operations. Water left in air lines can freeze during exposure to cold temperatures, blocking flow or rupturing pipes. Compressor lubricant not captured in a coalescing filter will eventually collect in pneumatic components, causing premature component repair or replacement. Environmental concerns will be raised if oily, compressed air is continually discharged into the atmosphere through a pneumatic muffler.


H Series Features and Benefits
• Coalescing, particulate and adsorption filter elements available
• Optional indicators, gauges and drains
• Temperatures up to 450°F (232°C)
• Pressures to 500 PSIG (34 bar)
• Connection sizes from 1/4" to 3" NPT, BSPP & BSPT • Flows from 10 to 1660 SCFM (17-2822 m3/hr)

For more information or a detailed discussion about your specific requirements please contact us at 727-847-4900 or Toll Free at 800-761-4298.



*Scroll to the right to see entire chart.
PERFORMANCE CHARACTERISTICS
HEIGHT (MM) 180, 250, 280, 400, 475, 640, 750, 915
HEIGHT (INCH) 7, 10, 11, 15, 19, 25, 30, 36
WIDTH (MM) 79, 118, 152, 203
WIDTH (INCH) 3, 5, 6, 8
WEIGHT (LBS) 35, 1.89, 1.49, 34.14, 1.87, 1.47, 1.85, 1.44, 3.56, 4.11, 3.29, 12.11, 11.97, 15.99, 14.00
WEIGHT (KG) 16, 0.86, 0.68, 15.48, 0.85, 0.66, 0.84, 0.65, 1.61, 1.86, 1.49, 5.49, 5.43, 7.25, 6.35
ELEMENT REMOVAL CLEARANCE 2.99, 5.51, 6.5, 10, 13.5, 19.25, 24.02, 28.50
MAXIMUM FLOW RATE (M3/M) 19 @ 7 bar to 2822 @ 7 bar depending on housing and element chosen
MAXIMUM OPERATING TEMPERATURE AIR (C) 79, 232
MAXIMUM OPERATING TEMPERATURE AIR (F) 175, 450
BRAND Finite



Also Available from mdi: Parker Transair Aluminum Pipe and Fittings for Compressed Air

Transair aluminum pipe is the ideal system for compressed air, vacuum, and inert gas applications. It offers significant savings on installation, maintenance and operating costs when compared to traditional compressed air piping systems. Its removable and interchangeable components allow users to easily modify production layouts or execute process changes within minutes. It's the only product with true push-to-connect fittings, eliminating the need to thread, solder or glue pipe. Its unique sealing technology guarantees Transair to be leak-free.
Continue...


Also Available from mdi: Parker Air Dryers for Compressed Air

Parker Domnick Hunter was the original innovator of compressed air treatment, developing the modern technology which is still the benchmark today. Parker Air Dryer products and systems deliver a unique combination of innovation and excellence in the most demanding applications, helping engineers to maximise the productivity and profitability of their manufacturing and process operations and with a focus on delivering real and lasting value to every customer. DomnickHunterSales.com is your complete source for Parker Domnick Hunter Compressed Air Dryers, Gas Generators, Process Water Chillers, and Condensate Drains.
Continue...